Room Integrity Testing for Fire Suppression Systems
Need room integrity testing for a fire suppression system?
Air Tightness Solutions provides room integrity testing for contractors, fire suppression specialists and commercial projects across the UK.
We help project teams complete required testing efficiently, avoid delays to commissioning programmes and provide clear reporting following the completed test.
Whether you are working on a data centre, server room, archive facility, plant room or specialist protected environment, we can help arrange testing at the right stage of the project.
What is room integrity testing?
Room integrity testing, sometimes referred to as enclosure integrity testing, assesses how effectively a protected room can retain fire suppression gas following system discharge.
The test helps determine whether the room enclosure has been sealed sufficiently to maintain the required hold time for the suppression system to operate effectively.
Room integrity testing is commonly carried out on spaces protected by gaseous fire suppression systems, including:
- Server rooms
- Data centres
- Electrical switch rooms
- Communications rooms
- Archives and document storage
- Control rooms
- Plant rooms
- Specialist protected environments
Testing is often completed as part of the commissioning process before the suppression system becomes operational.
Why is room integrity testing important?
Gaseous fire suppression systems rely on the protected room remaining sufficiently sealed after discharge.
Excessive air leakage can reduce gas concentration levels too quickly and affect system performance.
- Testing helps confirm that:
- The enclosure can maintain the required hold time
- Leakage levels are within acceptable limits
- The suppression system can operate effectively
- The room has been sealed correctly
- Compliance requirements have been met
Identifying leakage issues before handover can help avoid delays, remedial works and retesting later in the programme.
Why choose Air Tightness Solutions?
Room integrity testing often takes place on specialist projects where timing, accuracy and communication are critical.
Clients choose Air Tightness Solutions because we provide:
- Value Engineered Advice
- Responsive & Reliable Service
- Fully Accredited
We provide compliant solutions with ATTMA accredited engineers for Air Testing.
When should room integrity testing be carried out?
Testing is typically completed once the protected room construction and sealing works have been finished.
This may include:
- Installation of doors and glazing
- Completion of service penetrations
- Installation of fire suppression systems
- Sealing of cable and pipe penetrations
- Completion of ceiling and floor interfaces
- Final sealing works
Testing too early can increase the likelihood of failed results or aborted visits if the room is not fully complete.
Our room integrity testing process
01. Initial enquiry
Send us your project information, specifications or drawings.
02. Review & quotation
We confirm the testing requirements, methodology and pricing.
03. Booking confirmation
Testing dates are arranged to suit the project programme.
04. Site attendance & testing
Our tester attends site and carries out the required room integrity assessment.
05. Results & certification
Following completion of the testing, we issue the relevant documentation and results.
Need to arrange a test quickly? Contact our team and we’ll advise on current availability.
Common causes of room leakage
Air leakage within protected rooms is commonly caused by:
- Unsealed cable penetrations
- Poorly sealed pipe penetrations
- Door perimeter leakage
- Ceiling void leakage paths
- Raised floor leakage
- Gaps around ductwork
- Incomplete sealing works
Identifying these issues early can help reduce delays and remedial works later in the project.
Supporting fire suppression contractors and project teams
We understand that room integrity testing is often one part of a wider commissioning and compliance programme.
Our team works closely with contractors and specialists to help ensure testing is carried out efficiently and with minimal disruption wherever possible.
We can also help explain:
- Testing requirements
- Preparation guidance
- Common leakage areas
- Reporting expectations
- Next steps following testing
Frequently asked questions
Room integrity testing assesses how effectively a protected enclosure can retain fire suppression gas after discharge.
Testing helps confirm that the room enclosure can maintain the required hold time for the fire suppression system to operate effectively.
Testing is commonly carried out on server rooms, data centres, switch rooms, archives, plant rooms and other protected environments.
Areas of excessive leakage may require remedial sealing works before retesting is completed.
Reporting and certification are typically issued promptly following the completed test.
What Our Clients Say About Us
Carol Keith
Andy Nelmes
Need a quote for room integrity testing?
Whether you require testing for a single protected room or multiple environments across a larger project, Air Tightness Solutions can help.
We provide reliable testing, responsive communication and clear reporting to support project compliance and completion.
Need a quote for room integrity testing?
- Site postcode
- Project details
- Number of protected rooms
- Preferred testing dates
- Contact details
- College Offices, Watery Lane Wantage, OX12 9PL
- Mon - Fri: 8.00 -18:30